Seite 1 - Operating Instructions

pLevel and PressureOperating InstructionsHydrostatic pressuretransmitters D81

Seite 2 - Note Ex area

10 Pressure transmitter D81WeightsPressure transmitter D81 approx. 1.6 … 10 kg (depending on isolatingsystem)External housing approx. 400 gAdjustment

Seite 3 - Pressure transmitter D81 3

Pressure transmitter D81 11Product descriptionSupply and signal circuit (analogue transmission, 4 … 20 mA),additional data for electronics version LSu

Seite 4 - 1 Product description

12 Pressure transmitter D81Protective measures 1)Protection IP 66, IP 67, IP 68VEGABOX 01 IP 66 and IP 67Protection class IIIOvervoltage category IIIA

Seite 5 - Pressure transmitter D81 5

Pressure transmitter D81 13Product descriptionOperating conditionsAmbient conditionsAmbient temperature -40°C … +85°C- with display module -10°C … +60

Seite 6 - Electronics version I:

14 Pressure transmitter D811.6 Approvals and certificatesApprovals- Ex Zone 2- CENELEC EEx ia IIC- ATEX II 1G EEx ia IICIf the use of approved instrum

Seite 7 - , VVO adjustable

Pressure transmitter D81 15Process connections D811.7 DimensionsHousingProduct descriptionø 7667ø 7591ø 41,64663ø 41,693ø 41,64690d2d4kDf51100bFA, FB,

Seite 8

16 Pressure transmitter D81Product descriptionDdMbD2D1Ld6D2L2gDMb60Tube isolating diaphragm with connection acc. toDIN 11 851Order DN PN G1 L2 D2 d6 g

Seite 9 - 1.5 Technical data

Pressure transmitter D81 17Product description8510811813538 72ø 5M20x1,513013972100with protective coverVEGABOX 01

Seite 10 - 18 24 30 36

18 Pressure transmitter D81Mounting2 Mounting2.1 Mounting instructionsThe pressure transmitter can be mounted inany position. Cable entries must point

Seite 11 - Pressure transmitter D81 11

Pressure transmitter D81 19Electrical connection3 Electrical connection3.1 Connection instructionsThe electronics in the pressure transmitterrequires

Seite 12

2 Pressure transmitter D81ContentsContentsSafety information ... 2Note Ex area ..

Seite 13 - Operating conditions

20 Pressure transmitter D81Electronics version K4 … 20 mA output signal with integratedadjustment and remote parameter settingthrough PC and HART® han

Seite 14 - 14 Pressure transmitter D81

Pressure transmitter D81 21Electrical connection3.3 Connection to external connection housing VEGABOX 01Zum Anschluss anDruckmessumformer mitanalogem

Seite 15 - 1.7 Dimensions

22 Pressure transmitter D81Electrical connectionSupply through a VEGA signal conditioning instrumentStandard wiring for non-standardised output.Supply

Seite 16

Pressure transmitter D81 23Setup4 Setup4.1 Adjustment structureThe hydrostatic pressure transmitters comewith or without adjustment capability.After c

Seite 17 - VEGABOX 01

24 Pressure transmitter D81Adjustment with PC and adjustmentprogram VVO (electronics version B, I, Kand L)With the adjustment program VVO (VEGAVisual

Seite 18 - 2 Mounting

Pressure transmitter D81 25SetupAdjustmentFor adjustment of zero and span, an amme-ter must be connected to terminals 1 and 3.The measured value is id

Seite 19 - 3 Electrical connection

26 Pressure transmitter D81 250 Ω Ri < 250 Ω +-PLCSetup4.4 Setup with HART® handheldSensors with electronics versions I, K and Lcan be set up with

Seite 20 - Klemmeinsatz

Pressure transmitter D81 27SetupThe most important adjustment stepsOn the following four pages you see a menuschematic of the HART® handheld in conjun

Seite 21

28 Pressure transmitter D81SetupHART® menu schematic123451.1 4.1(5.1) 4.2(5.2)Less importantmenu windowsNot required, unimportantor blocked menu windo

Seite 22 - + -

Pressure transmitter D81 29SetupBlocked menu. Thefollowing menu window isindicated but not supportedby the sensor. Thereforesaving of adjustmentscarri

Seite 23 - 4.1 Adjustment structure

Pressure transmitter D81 33 Electrical connection3.1 Connection instructions ... 193.2 Terminal assi

Seite 24 - 4.2 Sensor without adjustment

30 Pressure transmitter D81SetupHART® menu schematic (continuation)1.3.31.3.46 Write protect None7 Descriptor8 Message9 PV Snsr s/nFinal asmbly num 0R

Seite 25 - Integration time

Pressure transmitter D81 31Setup1.2.3.1.11.2.3.1.2Note:After entering a parameter, push "ENTER" and then "SEND".Confirm the messag

Seite 26 - handheld

32 Pressure transmitter D812221) Ri < 250 Ω 4 ... 20 mA Setup5.5 Adjustment with PC directly on the sensor(electronics versions I, K and L)For conn

Seite 27 - Pressure transmitter D81 27

Pressure transmitter D81 33SetupIf you have already connected the PC withthe adjustment software VVO to your measur-ing system,• first switch on the p

Seite 28 - menu schematic

34 Pressure transmitter D81• Confirm the adjustment with " " and aftersaving you are again in the initial menu.SetupNote:If you connect the

Seite 29 - Pressure transmitter D81 29

Pressure transmitter D81 35You can carry out the min./max. adjustmentwith or without medium. Generally you willcarry out the adjustment without medium

Seite 30 - 30 Pressure transmitter D81

36 Pressure transmitter D81• Click to " ".• When the sensor is unpressurised and ininstallation position, confirm the safetyenquiry with &qu

Seite 31 - Pressure transmitter D81 31

Pressure transmitter D81 37You can choose four linearisation curves:linear, horiz. cylindrical tank, spherical tankand user programmable curve.Under &

Seite 32

38 Pressure transmitter D81Max. 32 index markers (value pairs) can beentered.• Quit the menu with " ".• Confirm the message with " &quo

Seite 33 - User access

Pressure transmitter D81 39Saved sensor data can be transferred lateron to other sensors.For example, if you have a system with sev-eral of the same s

Seite 34 - Configuration/Measuring

4 Pressure transmitter D81Product description1 Product description1.1 Function and configurationThe pressure transmitter D81 is an efficientinstrument

Seite 35 - Pressure transmitter D81 35

40 Pressure transmitter D81Diagnostics6 DiagnosticsMaintenanceThe pressure transmitter D81 is maintenancefree.Should dismounting of the pressure trans

Seite 36 - Parameter adjustment

Pressure transmitter D81 41Instrument modification7 Instrument modification7.1 Retrofitting the adjustment insertSuch a retrofitting can be necessary,

Seite 37 - Offset correction

42 Pressure transmitter D81Notes

Seite 38 - 38 Pressure transmitter D81

Pressure transmitter D81 43Notes

Seite 39 - Meas. data info

ISO 9001All statements concerning scope of delivery, application, practicaluse and operating conditions of the sensors and processing sys-tems corresp

Seite 40 - 6 Diagnostics

Pressure transmitter D81 5Product description1.2 Electronics version without adjustmentElectronics version B:Pressure transmitter for connection to VE

Seite 41 - 7 Instrument modification

6 Pressure transmitter D81Product descriptionElectronics version I:Pressure transmitter 4 … 20 mA, HART®, VVOVVO512344-20mAterminalKlemmeinsatz+-12V..

Seite 42 - 42 Pressure transmitter D81

Pressure transmitter D81 71.3 Electronics version with integrated adjustment in connection housingElectronics version K:Pressure transmitter 4 … 20 mA

Seite 43 - Pressure transmitter D81 43

8 Pressure transmitter D811.4 Electronics for connection to VEGADIS 12VEGADIS 12DISPLAY+ -TRANSMITTER5876321101112OPERATEPOINTDISPLAYTRANSMITTERENDZE

Seite 44 - ISO 9001

Pressure transmitter D81 9Product description1.5 Technical dataMechanical dataMaterials, wetted partsProcess connection stainless steel 1.4571Diaphrag