KFA6-SR2-Ex2.W
Isolated switch amplifiers
Input I EEx ia IIC Input II EEx ia IIC
green
red red
Output I
Output II
Power
Rail
LB/SC
collective
error message
Switch S3 in position I
Switch S3 in position I
Switch S3 in position I
Switch S3 in position II
Power
supply
only
KFD2-SR2-Ex2.W
LB
SC
LB
SC
Safe area
Hazardous area,
zone 0, zone 1
yellow yellow
without
LB, SC
without SC
1+ 3-
1+ 3-
1+ 3-
2+
3-2+
3-1+
S1 S2
S3 S3
II
I
II
I
1
10 k
10 k
14 15
400 Ω ≤ R 2 k
4+ 6-
4+ 6-
4+ 6-
5+
6-5+
6-4+
10 k
10 k
400 Ω ≤ R 2 k
789 101112
+-
+-
&&
Composition
230 V AC
2-channel
Control circuit EEx ia IIC
Reversible mode of operation
1 relay output with 1 changeover
contact per channel
EMC acc. to NAMUR NE 21
LB/SC monitoring
Usable up to SIL 2 acc. to IEC 61508
The transformer isolated barrier
transfers digital signals from the
hazardous area. Sensors per
DIN EN 60947-5-6 (NAMUR) and
mechanical contacts may be used as
alarms. Control circuits are monitored
for lead breakage (LB) and short circuit
(SC). The external faults are indicated
according to NAMUR NE44 by a red
flashing LED. For type KFD2-SR2-
Ex2.W, an LB/SC collective error
message is in addition transferred
through the Power Rail to the power
feed module. The intrinsically safe
inputs per DIN EN 50020 are safely
isolated from the output and the power
supply. Relay outputs are galvanically
separated from the mains power in
accordance with IEC 61140. Relay
outputs are galvanically separated from
each other in accordance with
IEC 61140.
Function
Output: relay
Seitenansicht 0
1 2 3

Inhaltsverzeichnis

Seite 1 - Composition

1103373_ENG.xml 2003-03-25Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in GermanyPepperl+Fuchs Grou

Seite 2 - Technical Data

2Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in GermanyPepperl+Fuchs Group • Tel.: Germany +49 621

Seite 3 - Supplementary information

3103373_ENG.xml 2003-03-25Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in GermanyPepperl+Fuchs Grou

Kommentare zu diesen Handbüchern

Keine Kommentare