Vega KFD2-SR2-Ex2.2S Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Ausrüstung Vega KFD2-SR2-Ex2.2S herunter. VEGA KFD2-SR2-Ex2.2S User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Release date 2010-02-02 18:14 Date of issue 2010-03-19 181284_ENG.xml
KFD2-SR2-Ex2.2S
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany +49-621-776-0 • USA +1-330-4253555 • Singapore +65-67-799091 • Internet www.pepperl-fuchs.com
1
Switch Amplifier
2+
3-
1+
Zone 2
Div. 2
Zone 0, 1, 2
Div. 1, 2
KFD2-SR2-Ex2.2S
7
8
9
I
II
III
IV
I
II
24 V DC
14+
15-
Power Rail
24 V DCERR
5+
6-
4+
10 kΩ
10 kΩ
400 Ω ≤ R 2 k
10 kΩ
10 kΩ
400 Ω ≤ R 2 k
10
11
12
Connection
Assembly
2-channel isolated barrier
24 V DC supply (Power Rail)
Dry contact or NAMUR inputs
2 x 2 relay contact outputs with AND logic
Line fault detection (LFD)
Reversible mode of operation
Up to SIL2 acc. to IEC 61508
Function
This isolated barrier is used for intrinsic safety applications. It
transfers digital signals (NAMUR sensors/mechanical
contacts) from a hazardous area to a safe area.
Each sensor or switch controls two form A normally open
relay contacts for the safe area load. The normal output state
can be reversed using switches S1 and S2. Switch S3 is used
to enable or disable line fault detection of the field circuit.
During an error condition, the relays revert to their de-
energized state and the LEDs indicate the fault according to
NAMUR NE44.
A unique collective error messaging feature is available when
used with the Power Rail system.
Features
1
3
4
6
2
5
13 15
12
9
10
7
14
11
8
KFD2-SR2-Ex2.2S
1
2
OUT CHK PWR
S2
S1
S3
III
Front view
Switch S3
(LB/SC-monitoring)
LED yellow:
Relays channel Ι
LED red:
LB/SC channel Ι
LED yellow:
Relays channel ΙΙ
LED red:
LB/SC channel ΙΙ
LED green:
Power supply
Removable terminals
green
Removable terminals
blue
Switch S1
(Mode of operation channel Ι)
Switch S2
(Mode of operation channel ΙΙ)
2
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Div. 1, 2

Release date 2010-02-02 18:14 Date of issue 2010-03-19 181284_ENG.xmlKFD2-SR2-Ex2.2SSubject to reasonable modifications due to technical advances.

Seite 2

Release date 2010-02-02 18:14 Date of issue 2010-03-19 181284_ENG.xmlTechnical data KFD2-SR2-Ex2.2SSubject to reasonable modifications due to techni

Seite 3

Release date 2010-02-02 18:14 Date of issue 2010-03-19 181284_ENG.xmlTechnical data KFD2-SR2-Ex2.2SSubject to reasonable modifications due to techni

Seite 4 - 13 14 15

Release date 2010-02-02 18:14 Date of issue 2010-03-19 181284_ENG.xmlTechnical data KFD2-SR2-Ex2.2SSubject to reasonable modifications due to techni

Kommentare zu diesen Handbüchern