Operating InstructionsPressure transmitter with METEC® measuring cellVEGABAR 55Foundation Fieldbus - climate compensatedDocument ID: 39443
103 Product descriptionVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303213.3 OperationThe instrument can be adjusted with the follo
113 Product descriptionVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321parameter adjustment of these instruments, an adjustment s
124 MountingVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303214 Mounting4.1 General instructionsMake sure that all parts of the in
134 MountingVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-13032121212112Fig. 4: Position of the lter element1 Filter element2 Blin
144 MountingVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303214.2 Mounting stepsFormountingVEGABAR55,aweldedsocketisrequir
155 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303215 Connecting to power supply5.1 Preparing the con
165 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321low frequency potential equalisation currents are t
175 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Fig. 7: Connection steps 6 and 7Proceed as follows:
185 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Information:The cable gland can be mounted in three
195 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321I2CDisplay112 5 678Fig. 10: Wiring plan, single cha
2ContentsVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Contents1 About this document1.1 Function ...
205 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321123Display12I2CFig. 12: Connection compartment, dou
215 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303215.5 Wiring plan, double chamber housing Ex dI²C231
225 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321112Fig. 16: Wiring plan, Ex-d double chamber housin
235 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321I²CDisplayTyp:12 5678BusSim.456123Fig. 19: Electron
245 Connecting to power supplyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321I2CDisplay112 5 678Fig. 21: Wiring plan external el
256 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303216 Set up with the disp
266 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Fig. 22: Insert display
276 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321 – Save value• [->]
286 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321The actual measured val
296 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Density0001000kg/dm³6.
3ContentsVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303218 Maintenanceandfaultrectication8.1 Maintain ...
306 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Iftheadjustmentrange
316 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321The display and adjustm
326 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321The adjustment unit is
336 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Proceed as follows:1.
346 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321ResetBasic adjustmentPe
356 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Basic adjustment▶Basic
366 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321ServiceBasic adjustment
377 Set up with PACTware and other adjustment programsVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303217 Set up with PACTware and
387 Set up with PACTware and other adjustment programsVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303217.2 Parameter adjustment w
398MaintenanceandfaultrecticationVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303218 Maintenanceandfaultrectication8.1 Ma
41 About this documentVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303211 About this document1.1 FunctionThis operating instructio
408MaintenanceandfaultrecticationVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Error Cause RecticationWhen an addition-al
418MaintenanceandfaultrecticationVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321• Ftotal: Total deviation• Fperf: Basic acc
428MaintenanceandfaultrecticationVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321You can view all software histories on our
438MaintenanceandfaultrecticationVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321• Please ask the agency serving you for the
449 DismountingVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303219 Dismounting9.1 Dismounting stepsWarning:Before dismounting, be
4510 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-13032110 Supplement10.1 Technical dataGeneral dataPressure type Gauge p
4610 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321 Ʋ Connection cable with IP 68 1 bar versionPE,PURWeight approx.
4710 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Adjustmentrangeofthezero/spanadjustmentrelatingtothenomin
4810 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Nominalrange Overload capacity, max. pressureOverload capacity, m
4910 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321InuenceoftheproductorambienttemperatureAveragetemperature
52 For your safetyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303212 For your safety2.1 Authorised personnelAll operations descr
5010 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303210,15 %-0,15 %-40°C -20°C20°C40°C 60°C 80°CFig. 27: Thermal change,
5110 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321 Ʋ with cooling element and screening sheet-12 … +200 °C (+10 … +3
5210 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321 Ʋ Tensile strength > 1200 N (270 pounds force) Ʋ Standard leng
5310 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321 Ʋ Ex ia instrument 9 … 24 V DC Ʋ Ex d instrument 9 … 32 V DCOpera
5410 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321tiSimulateALARMSOutPVFIELD-VALUEMode & StatusPVF-TIMELOW-CUTOF
5510 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321• secondary_value_2 – Valueaftermin/max-adjustment.Selectedas
5610 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321 – Highest calibrated value. For calibration of the high limit poi
5710 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Aluminium housing21ø 86 mm (3.39")~ 116 mm (4.57")116 mm
5810 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321Stainless steel housing~ 69 mm(2.72")ø 79 mm(3.11")117 m
5910 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321External housing with version IP 681265 mm(2.68")68 mm(2.68&q
62 For your safetyVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303212.6 CE conformityThisdevicefulllsthelegalrequirementsof
6010 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321VEGABAR55,threadedttingGG GL - 180°CGNGG - 180°C/200°CBA / BB
6110 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321VEGABAR55,hygienictting178 mm(3 5/64")78 mm(3 5/64"
6210 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321VEGABAR55,hygienictting278 mm(3 5/64")78 mm(3 5/64"
6310 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321VEGABAR55,angeconnection3 15/32"4 1/64"5 7/16"
6410 SupplementVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-13032110.4 Industrial property rightsVEGA product lines are global prot
65INDEXVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321INDEXAAccessories – Display and adjustment module 10 – External display a
66NotesVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321
67NotesVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321
Printing date:VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany39443-EN-130321All statements concerning scope of delivery, application, practi
73 Product descriptionVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-1303213 Product description3.1 CongurationThe scope of deliver
83 Product descriptionVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321213Fig. 1: Example of a VEGABAR 55 with process tting G1½
93 Product descriptionVEGABAR 55 • Foundation Fieldbus - climate compensated39443-EN-130321This operating instructions manual applies to the following
Kommentare zu diesen Handbüchern