Vega VEGAFLEX series 80 - External housing Bedienungsanleitung Seite 15

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 24
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 14
15
9 Supplement
External housing • VEGAFLEX 80 series
46802-EN-131120
Ambient, storage and transport temperature on the instrument housing
Ʋ without display and adjustment
module
-40 … +80 °C (-40 … +176 °F)
Ʋ With display and adjustment module -20 … +70 °C (-4 … +158 °F)
Electromechanical data
Cable entry/plug
1)
Ʋ Instrument housing 1 x cable gland M20 x 1.5 (cable: ø 6 … 12 mm), 2 x
blind plug M20 x 1.5
or:
1 x closing cap ½ NPT, 2 x blind plug ½ NPT
or:
1 x plug (depending on the version), 2 x blind plugs
M20 x 1.5
Ʋ Housing base 1 x N-socket
Ʋ Sensor housing 1 x N-socket
Spring-loaded terminals for wire cross-section up to 2.5 mm² (AWG 14)
Electrical protective measures
Protection rating
Ʋ Sensor housing IP 66/IP 68 (1 bar)
Ʋ Instrument housing - Instrument
socket
IP 66/IP 67
1)
Depending on the version M12 x 1, according to ISO 4400, Harting, 7/8" FF.