Operating InstructionsConductive probe EL 1Document ID:32651Conductive
4.2 Mounting instructionsDue to agitators, equipment vibration or similar, the level switch can besubjected to strong lateral forces.Extreme vibration
Fig. 4: InflowingmediumThe probe should protrude into the vessel to avoid buildup. For thatreason, avoid using high mounting bosses for screw-in fitting
5 Connecting to power supply5.1 Preparing the connectionAlways keep in mind the following safety instructions:l Connect only in the complete absence o
Fig. 6: Componentfor line break monitoring in conjunction with VEGATOR 6321 Open the terminal of the measuring rod and attach the component.2 Connect
Take note of the operating instructions manual of the signalconditioning instrument.14 Conductive probe EL 15 Connecting to power supply32651-EN-10020
6 Setup6.1 General informationYou can find the setup procedure for EL 1 in the operating instructionsmanual of the corresponding signal conditioning in
7 Maintenance and fault rectification7.1 MaintenanceWhen used as directed in normal operation, EL 1 is completelymaintenance free.7.2 Rectify malfuncti
l Attach the completed form and, if need be, also a safety datasheet outside on the packagingl Please ask the agency serving you for the address of yo
8 Dismounting8.1 Dismounting stepsWarning:Before dismounting, be aware of dangerous process conditions suchas e.g. pressure in the vessel, high temper
9 Supplement9.1 Technical dataGeneral dataMaterials 316Ti corresponds to 1.4571, 316L corresponds to 1.4404 or 1.4435Materials, wetted parts- Process
Contents1 About this document1.1 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.2 Target group . . . . . . . . . . . .
Electrical protective measuresProtection rating IP 66/IP 67ApprovalsDepending on the version, instruments with approvals can have different technical d
9.2 Dimensions~43 mm(1 11/16")46 mm(1 13/16")54 mm (2 1/8")SW 41 mm(1 39/64")G½A 18 mm(45/64")ø10 mm(25/64") LL1ø8 mm(5/
9.3 Industrial property rightsVEGA product lines are global protected by industrial property rights.Further information see http://www.vega.com.Only i
Conductive probe EL 1 239 Supplement32651-EN-100208
VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermanyPhone +49 7836 50-0Fax +49 7836 50-201E-mail: [email protected] date:ISO 9
1 About this document1.1 FunctionThis operating instructions manual provides all the information youneed for mounting, connection and setup as well as
2 For your safety2.1 Authorised personnelAll operations described in this operating instructions manual must becarried out only by trained specialist
2.5 Safetyinstructions for Ex areasPlease note the Ex-specific safety information for installation andoperation in Ex areas. These safety instructions
3 Product description3.1 ConfigurationThe scope of delivery encompasses:l EL 1 point level sensorl Documentation- this operating instructions manual- E
The serial number allows you to access the delivery data of theinstrument viawww.vega.com, "VEGA Tools" and "serial numbersearch".
The packaging of standard instruments consists of environment-friendly, recyclable cardboard. For special versions, PE foam or PE foilis also us ed. D
4 Mounting4.1 General instructionsIn general the level switch can be mounted in any position. Theinstrument must be mounted in such a way that the pro
Kommentare zu diesen Handbüchern