3 Product description
VEGABAR 52 • Foundation Fieldbus
36720-EN-130321
Instruments with double seal have an additional front seal.
Instrumentswithhygienicttingareequippedwithagap-freeform
seal.
Power is supplied via the H1 Fieldbus. A two-wire cable according to
Fieldbusspecicationservesascarrierofbothpoweranddigitaldata
for multiple sensors. This cable can be operated in two versions:
via an H1 interface card in the control system and additional power
supply
via a Linking device with HSE (High speed Ethernet) and addi-
tional power supply according to IEC 61158-2
TheDD(DeviceDescriptions)andCFF(capabilityles)necessary
forplanningandcongurationofyourFF(FoundationFieldbus)com-
munication network are available in the download area of the VEGA
homepage www.vega.comunder"Services - Downloads - Software
- Foundation Fieldbus".Theappropriatecerticatesarealsoavailable
there.ACDwiththeappropriatelesandcerticatescanbeordered
via e-mail under info@de.vega.com or by phone from one of the
VEGAagenciesundertheordernumber"DRIVER.S".
The backlight of the display and adjustment module is powered by the
sensor. Prerequisite is a certain level of operating voltage.
Thedataforpowersupplyarespeciedinchapter"Technical data".
Theoptionalheatingrequiresitsownoperatingvoltage.Youcannd
detailsinthesupplementaryinstructionsmanual"Heating for display
and adjustment module".
This function is generally not available for approved instruments.
3.3 Operation
The instrument can be adjusted with the following adjustment media:
With the display and adjustment module
with the suitable VEGA DTM in conjunction with an adjustment
software according to the FDT/DTM standard, e.g. PACTware and
PC
acongurationtool
3.4 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging of standard instruments consists of environment-
friendly, recyclable cardboard. For special versions, PE foam or PE
foil is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out under consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause