54
10 Supplement
VEGABAR 67 • Foundation Fieldbus - climate compensated
39446-EN-130321
Process conditions
Thespecicationsofthepressurestageandproducttemperatureareusedasanoverview.The
specicationsonthetypelabelareapplicable.
Process pressure
Ʋ with measuring ranges 0.1 bar
(1.45 psig) or 0.2 bar (2.9 psig)
max. 15 bar (217.6 psig) or max. 20 bar (290 psig)
12)
Ʋ with meas. ranges from 0.4 bar
(5.8 psig)
max. 25 bar (363 psig)
13)
Pressurestage,processtting
Ʋ Threadedtting 316L PN 3, PVDF PN 5
14)
Ʋ Thread 316LPN25,PVDFunpressurized
Ʋ Locktting Unpressurized
Product temperature
Ʋ Suspension cable -12 … +100 °C (+10 … +212 °F)
Ʋ Connection tube -12 … +100 °C (+10 … +212 °F)
Vibration resistance mechanicalvibrationswith4gand5…100Hz
15)
With version with connection tube, vibration resistance 1 g. With lengths > 0.5 m (1.64 ft) the tube
must be supported in addition.
Shock resistance
Acceleration 100 g/6 ms
16)
Electromechanical data - version IP 66/IP 67
Cable entry/plug
17)
Ʋ Single chamber housing – 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind plug M20 x 1.5
or:
– 1 x closing cap ½ NPT, 1 x blind plug ½ NPT
or:
– 1␣xplug(dependingontheversion),1␣xblindstopper
M20␣x␣1.5
or:
– 2 x blind plug M20 x 1,5
12)
Limited by the overpressure resistance of the measuring cell.
13)
Limitation by the pressure-tightness of the cable connection.
14)
Limited by the overpressure resistance of the measuring cell.
15)
Tested according to the guidelines of German Lloyd, GL directive 2.
16)
Tested according to EN 60068-2-27.
17)
DependingontheversionM12x1,accordingtoISO4400,Harting,7/8"FF.
Kommentare zu diesen Handbüchern