10 Supplement
VEGABAR 55 • Foundation Fieldbus - climate compensated
39443-EN-130321
Adjustmentrangeofthezero/spanadjustmentrelatingtothenominalmeasuringrange:
Ʋ zero -20 … +95 %
Ʋ Span -120 … +120 %
9)
Ʋ Dierencebetweenzeroandspan max. 120 % of the nominal range
Recommended max. turn down 10 : 1 (no limitation)
Nominalmeasuringrangesandoverloadcapabilityinbar/kPa
Thespecicationsareonlyanoverviewandrefertothemeasuringcell.Limitationsduetothema-
terialandversionoftheprocessttingarepossible.Thespecicationsonthenameplateapply.
Nominalrange Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
Gauge pressure
0 … +0.2 bar/0 … +20 kPa +20 bar/+2000 kPa -1 bar/-100 kPa
0 … +0.4 bar/0 … +40 kPa +30 bar/+3000 kPa -1 bar/-100 kPa
0 … +1 bar/0 … +100 kPa +35 bar/+3500 kPa -1 bar/-100 kPa
0 … +2.5 bar/0 … +250 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
0 … +5 bar/0 … +500 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
0 … +10 bar/0 … +1000 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
0 … +25 bar/0 … +2500 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
-1 … 0 bar/-100 … 0 kPa +35 bar/+3500 kPa -1 bar/-100 kPa
-1 … +1.5 bar/-100 … +150 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
-1 … +5 bar/-100 … +500 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
-1 … +10 bar/-100 … +1000 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
-1 … +25 bar/-100 … +2500 kPa +50 bar/+5000 kPa -1 bar/-100 kPa
-0.05 … +0.05 bar/-5 … +5 kPa +15 bar/+1500 kPa -1 bar/-100 kPa
-0.1 … +0.1 bar/-10 … +10 kPa +20 bar/+2000 kPa -1 bar/-100 kPa
-0.2 … +0.2 bar/-20 … +20 kPa +30 bar/+3000 kPa -1 bar/-100 kPa
-0.5 … +0.5 bar/-50 … +50 kPa +35 bar/+3500 kPa -1 bar/-100 kPa
Nominalmeasuringrangesandoverloadcapabilityinpsig
Thespecicationsareonlyanoverviewandrefertothemeasuringcell.Limitationsduetothema-
terialandversionoftheprocessttingarepossible.Thespecicationsonthenameplateapply.
Nominalrange Overload capacity, max.
pressure
Overload capacity, min. pres-
sure
Gauge pressure
0 … +3 psig +290 psig -15 psig
0 … +6 psig +430 psig -15 psig
0 … +15 psig +500 psig -15 psig
0 … +35 psig +700 psig -15 psig
0 … +70 psig +700 psig -15 psig
9)
Values less than -1 bar cannot be set.