Thermal change zero signal and output sp an with absolute pressure measuring range 0.1 bar,
reference
temperature 20 °C (68 °F):
- In the compensated temperature range
0 +100 °C (+32 +212 °F)
< (0.1 % + 0.1 % x TD)
- Outside the compensated temperature
range
< (0.15 % + 0.15 % x TD)
Applies also to instruments with analogue 4 20 mA current output and refers to the set span.
Thermal change, current output < 0.15 % at -40 +80 °C (-40 +176 °F)
Long-term stability (similar to DIN 16086, DINV 19259-1 and IEC 60770-1)
Applies to digital interfaces (HART, Probus PA, Foundation Fieldbus) as well as to analogue
current output 4 20 mA. Specications refer to the set span. Turn down (TD) = nominal
measuring range/set span.
Long-term drift of the zero signal < (0.1 % x TD)/year
Ambient conditions
Ambient, storage and transport temperature -40 +80 °C (-40 +176 °F)
Process conditions
The specications to the pressure stage and the product temperature are used as an overview.
The specications of the type label are applicable.
Pressure stage, process tting
- Thread 316L PN 60
- Thread Aluminium PN 25
- Thread PVDF PN 10
- Hygienic ttings 316L PN 6, PN 10, PN 25, PN 40
- Flange 316L PN 16, PN 40,150 lbs, 300 lbs, 600 lbs
- Flange with extension 316L without PN specication, PN 16, PN 40 or 150 lbs,
300 lbs, 600 lbs
- Flange PVDF PN 16
Product temperature standard version, depending on the meas. cell seal
10)
- FKM (VP2/A) -20 +120 °C (-4 +248 °F)
- EPDM (A+P 75.5/KW75F) -40 +120 °C (-40 +248 °F), 1 h: 140 °C/284 °F
cleaning temperature
- FFKM (Kalrez 63 75) -10 +120 °C (+14 +248 °F)
- FFKM (Chemraz 535) -30 +120 °C (-22 +248 °F)
Product temperature version with extended temperature range, depending on the meas. cell seal
as well as order specication
- FKM (VP2/A) -20 +150 °C (-4 +302 °F)
- EPDM (A+P 75.5/KW75F) -40 +150 °C (-40 +302 °F)
10)
With process tting PVDF, max. 100 °C (212 °F).
58 VEGABAR 64 4 20 mA/HAR
T
10 Supplement