Vega VEGABAR 52 Foundation Fieldbus Bedienungsanleitung Seite 59

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 58
59
10Приложение
VEGABAR 52 • Foundation Fieldbus
36720-RU-130320
XandYvaluesfortheuserdenedlinearizationcurve
curve_points_11_20
XandYvaluesfortheuserdenedlinearizationcurve
curve_points_21_30
XandYvaluesfortheuserdenedlinearizationcurve
curve_points_31_33
XandYvaluesfortheuserdenedlinearizationcurve
curvestatus
Resultoftableplausibilitycheck
"0:""Uninitialized""1:""Good""2:""Notmonotonousincreasing""3:""Notmonotonous
decreasing""4:""Notenoughvaluestransmitted""5:""Toomanyvaluestransmitted""6:
""Gradientofedgetoohigh""7:""Valuesnotexcepted""8:""Tablecurrentlyloaded""9:
""Sortingandcheckingtable"""
SUB_DEVICE_NUMBER
SENSOR_ELEMENT_TYPE
0:"non-specic"
display_source_selector
Selectsthetypeofvaluethatisdisplayedontheindication-/adjustement-module
"0:""Physicalvalue""1:""Percentvalue""2:""Linpercentvalue""6:""Out(AI1)""7:""Level""8:
""Out(AI2)""9:""Out(AI3)"""
max_peak_sensor_value
Holdsthemaximumsensorvalue.Writeaccessresetstocurrentvalue.Unitderivesfrom
'Sensor_range.unit'
Writeaccessresetstocurrentvalue
min_peak_sensor_value
Holdstheminimumsensorvalue.Writeaccessresetstocurrentvalue.Unitderivesfrom
'Sensor_range.unit'
Writeaccessresetstocurrentvalue
CAL_POINT_HI
Highestcalibratedvalue.Forcalibrationofthehighlimitpointyougivethehighmeasurement
value(pressure)tothesensorandtransferthispointasHIGHtothetransmitter.Unitderives
from'Sensor_range.unit'
CAL_POINT_LO
Lowestcalibratedvalue.Forcalibrationofthelowlimitpointyougivethelowmeasurement
value(pressure)tothesensorandtransferthispointasLOWtothetransmitter.Unitderives
from'Sensor_range.unit'
CAL_MIN_SPAN
Minimumcalibrationspanvalueallowed.Necessarytoensurethatwhencalibrationisdone,
thetwocalibratedpoints(highandlow)arenottooclosetogether.Unitderivesfrom'Sensor_
range.unit'
SCALE_IN
Min/max-adjustment:Upperandlowercalibratedpointsofthesensor.Unitderivesfrom
'Sensor_range.unit'
trimmed_value
Sensorvalueafterthetrimprocessing.Unitderivesfrom'Sensor_range.unit'
sensor_sn
Sensorserialnumber
temperature
Processtemperature.SelectedasinputtoAIFBbysetting'Channel'=4.Unitderivesfrom
'Temperature.unit'
temperature_unit
Unitcodeof'Temperature','Max/Min_peak_temperature_value'
°C,°F,K,°R
Seitenansicht 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 75 76

Kommentare zu diesen Handbüchern

Keine Kommentare