Vega INSYS Modem GPRS 5.0 Bedienungsanleitung Seite 92

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 113
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 91
GPRS General INSYS GPRS 5.0 serial
92
8.8.1.2 Data logger user data
A data logger message has the following setup:
Device ID 4 byte
2 x 8 bit for the digital inputs 2 byte
4 x 16 bit for the analogue inputs 8 byte
Checksum 1 byte
Total 15 byte
8.8.1.3 User data acknowledge of the control center
As an option, the data logger/control center software can be configured so that
for a data logger message an acknowledging message of the control center (user
data acknowledge) is sent.
Set-up:
Command (e.g. ACK) 1 byte
Checksum 1 byte
Total 2 byte
8.8.2 General data amount
For GPRS, such as for all IP-based transmission methods, the user data of the ap-
plication are packed into a TCP/IP message and sent to the remote terminal
(PUSH); the TCP/IP stack of the remote terminal (e.g. Windows) must acknowledge
each received TCP/IP message.
With GPRS, all data accumulated by the user from the IP level (incoming and out-
going) are calculated.
8.8.2.1 Transmission of user data without user data acknowledge of the remote termi-
nal
Application
/
GPRS modem
control center
D
a
t
a:
15
T
C
P
/
I
P
P
U
S
H
:
4
0
D
a
t
a:
0
T
C
P
/
I
P
A
C
K
:
40
Total: 95 byte
Seitenansicht 91