1
> 500 mm
Fig. 16: VEGAPULS 61 in a bypass
tube. The polarisation marking on the
process tting must be in one plane with the tube holes or the tube connection
openings.
1 Marking of the polarisation direction
When the sensor is mounted on a bypass tube, the distance from
VEGAPULS 61 to the upper tube connection should be approx.
500 mm (19.69 in) or more. In case of extremely rough tube inner
walls, you should use an inserted tube (tube in tube) or a radar sens or
with tube antenna.
The short examples are meant to give only introductory information on
the ow measurement. Planning information is available from ume
manufacturers and in special literature.
Meas. wall with rectangular ume
In general, the following points must be observed:
l Install the sensor on the headwater side
l Installation in the centre of the ume and vertical to the liquid
surface
l Distance to the overfall orice
l Distance of orice opening above ground
l Min. distance of the orice opening to bottom water
l Min. distance of the sensor to max. storage level
Flow measurement
VEGAPULS 61 4 20 mA/HART two-wire 21
4 Mounting