22
5 Connecting to power supply
VEGABAR 55 • Probus PA - climate compensated
39442-EN-130321
1
12
Fig. 17: Wiring plan, Ex-d double chamber housing
1 Voltage supply, signal output
5.6 Wiring plan - version IP 66/IP 68, 1 bar
1
2
Fig. 18: Wire assignment, connection cable
1 brown (+) and blue (-) to power supply or to the processing system
2 Shielding
5.7 Wiring plan, external housing with version
IP 68
Fig. 19: VEGABAR 55 in IP 68 version 25 bar and axial cable outlet, external
housing
Wiring plan
Wire assignment, con-
nection cable
Overview