6 Set up with the display and adjustment module
FIBERTRAC 31 • Probus PA
43833-EN-131119
In menu item"Channel" you determine which measured value the
output refers to.
In menu item "Scaling unit" you dene the scaling variable and the
scaling unit for the pulse rate on the display, e.g. volume in percent.
In menu item "Scaling" you dene the scaling format on the display
and the scaling of the measured values for 0 % and 100 %.
Measured value min.
Measured value max.
To damp process-dependent measured value uctuations, you can
set a time of 0 … 999 s in this menu item.
The default setting is a damping of 0 s.
In this menu item you can select which mode the sensor should oper-
ate in.
You can choose between overll and dry run protection.
The relay outputs of the sensor react accordingly.
Overll protection = the relay will deenergise (safe condition) when
the max. level is reached.
Dry run protection = the relay will deenergise (safe condition) when
the min. level is reached.
Setup - AI FB1 - Channel
Setup - AI FB1 - Scaling
unit
Setup - AI FB1 - Scaling
Setup - AI FB1 - Damping
Setup - Relay