Average temperature coecient of the span typ. < 0.2 %/10 K
Long-term stability (according to DIN 16086, DINV 19259-1 and IEC 60770-1)
Long-term drift of the zero signal
6)
< 0.2 %/year
Ambient conditions
Ambient temperature (note temperature derating!)
- Cable outlet -20 +80 °C (-4 +176 °F)
- Round plug connector M12 x 1 -25 +80 °C (-13 +176 °F)
- Angled plug connector according to
ISO 4400
-40 +80 °C (-40 +176 °F)
- Terminal housing -50 +80 °C (-58 +176 °F)
- with cooling element -20 +80 °C (-4 +176 °F)
2
1
55°C
(131°F)
80°C
(176°F)
130°C
(266°F)
150°C
(302°F)
Fig. 14: Temperature
derating VEGABAR 17
1 Ambient
temperature
2 Process
temperature
Storage and transport temperature
- Standard -30 +100 °C (-22 +212 °F)
- with cooling element -20 +100 °C (-4 +212 °F)
Process conditions
Product temperature
- Standard -30 +100 °C (-22 +212 °F)
- additional -30 +125 °C (-22 +257 °F)
- with cooling element -20 +150 °C (-4 +302 °F)
- Measuring ranges from 400 bar -30 +70 °C (-22 +158 °F)
Shock resistance
- Version with terminal housing 600 g according to IEC 60068-2-27 (mechanical
shock)