3 Product description
VEGABAR 51 • 4 … 20 mA/HART
36713-EN-130321
Unlessotherwiseindicated,thepackagesmustbestoredonlyunder
the following conditions:
Not in the open
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
Storageandtransporttemperatureseechapter"Supplement -
Technical data - Ambient conditions"
Relative humidity 20 … 85 %
3.5 Accessories and replacement parts
The display and adjustment module PLICSCOM is used for measured
value indication, adjustment and diagnosis. It can be inserted into the
sensor and removed at any time.
Youcanndfurtherinformationintheoperatinginstructions"Display
and adjustment module PLICSCOM"(Document-ID27835).
The interface adapter VEGACONNECT 4 enables the connection of
communication-capableinstrumentstotheUSBinterfaceofaPC.For
parameter adjustment of these instruments, an adjustment software
such as PACTware with VEGA-DTM is required.
Youcanndfurtherinformationintheoperatinginstructions"Interface
adapter VEGACONNECT"(Document-ID32628).
VEGADIS 61 is suitable for external measured value indication and
adjustment of plics® sensors. It is connected to the sensor with an up
to 25 m long, four-wire, screened standard cable.
Youcanndfurtherinformationintheoperatinginstructions"VE-
GADIS 61"(Document-ID27720).
VEGADIS 62 is suitable for measured value indication and adjustment
of sensors with HART protocol. It is looped into the 4 … 20 mA/HART
signal cable.
VEGADIS 62 is suitable for measured value indication with sensors
without HART protocol.
Youcanndfurtherinformationintheoperatinginstructions"VE-
GADIS 62"(Document-ID36469).
The measuring instrument holder is used for wall/tube mounting of
VEGABAR series 50 pressure transmitters and VEGAWELL 52 sus-
pension pressure transmitters. Supplied reducers enable the adapta-
tiontodierentinstrumentdiameters.Thematerialusedis316L.
Flangesareavailableindierentversionsaccordingtothefollowing
standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-1984,
GOST 12821-80.
Storage and transport
temperature
Display and adjustment
module
Interface adapter
External display and
adjustment unit
External display and ad-
justment unit VEGADIS 62
Measuring instrument
holder
Flanges