Seitenansicht 38
2 Conrm the menu "Basi
c adjustment" with [OK], the menu item
"Unit" will be displayed.
Unit
Unit of measurement
bar
Temperature unit
°C
3 Activate the selection with [OK] and sel ect "Units of measure-
ment with [->].
4 Activate the selection with [OK] and select the requested unit w ith
[->] (in the example mbar).
5 Conrm with [OK] and move to position correction with [->].
The adjustment unit is hence switched over from bar to mbar.
Proceed as follows to select the temperature unit:
7)
à Activate the selection with [OK] and select "Temperature unit
with [->].
à Activate the selection with [OK] and sel ect the requested unit with
[->] (e.g. °F).
à Conrm with [OK].
The temperature unit is hence switched over from °C to °F.
Proceed as follows:
1 Activate in the menu item "P osition correction" the selection with
[OK].
Position correction
Oset
P
=
+0000 mbar
53 mbar
2 Select with [->], e.g. to accept actual measured value.
Position correction
Accept current measured
value?
Accept
Edit
3 Conrm with [OK] and move to min.(zero) adjustment with [->].
Proceed as follows:
1 Edit the mbar value in the menu item "zero" with [OK].
7)
Selection options: °C, °F.
Carry out position cor-
rection
Carrying out zero ad-
justment
VEGABAR 61 Foundation Fieldbu
s 39
6 Set up with the indicating and adjustment module PLICSCOM
28258-EN-081209