14
4 Mounting
VEGABAR 81 • Probus PA
45020-EN-131107
1 2 3
4 4 4
Fig. 5: Position of the lter element - non-Ex, Ex-ia version
1 Housing plastic, stainless steel precision casting
2 Housing aluminium
3 Housing stainless steel, electropolished
4 Filter element
With the following instruments a blind plug is installed instead of the
lter element:
Instruments in protection IP 66/IP 68 (1 bar) - ventilation via capil-
laries in x connected cable
Instruments with absolut pressure
The lter element is integrated in the process assembly. It is located in
a rotatable metal ring and has the following function:
Atmospheric pressure compensation (with relative pressure meas-
uring ranges)
Turn the metal ring in such a way that the lter element points down-
ward after installtion of the instrument. This provides better protection
against buildup.
21
3
4
3
4
Fig. 6: Position of the lter element - Ex-d version
1 Single chamber housing, aluminium, stainless steel precision casting
2 Double chamber housing, aluminium, stainless steel precision casting
3 Rotatable metal ring
4 Filter element
Instruments with absolute pressure have a blind plug mounted
instead of the lter element.
Instruments in Ex-d ver-
sion