Operating InstructionsPressure transmitter with chemical sealVEGABAR 51Foundation FieldbusDocument ID: 36715
103 Product descriptionVEGABAR 51 • Foundation Fieldbus36715-EN-130321The delivery must be checked for completeness and possible transit damage immedi
113 Product descriptionVEGABAR 51 • Foundation Fieldbus36715-EN-130321The protective cover protects the sensor housing against soiling and intense hea
124 MountingVEGABAR 51 • Foundation Fieldbus36715-EN-1303214 Mounting4.1 General instructionsMake sure that all parts of the instrument coming in dir
134 MountingVEGABAR 51 • Foundation Fieldbus36715-EN-13032121212112Fig. 4: Position of the lter element1 Filter element2 Blind plugCaution:Duetot
144 MountingVEGABAR 51 • Foundation Fieldbus36715-EN-130321Instrumentsintheversion"Oil and grease free for oxygen"shouldbe unpacked ju
154 MountingVEGABAR 51 • Foundation Fieldbus36715-EN-13032190 mm (3.54")R 3,5 mm(0.14")3mm(0.12")70 mm (2.76")8 mm(0.32")93 m
165 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-1303215 Connecting to power supply5.1 Preparing the connectionAlways keep in
175 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321low frequency potential equalisation currents are thus suppressed, butth
185 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321Fig. 7: Connection steps 6 and 7Proceed as follows:1. Loosen the four sc
195 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321Information:The cable gland can be mounted in three positions each displa
2ContentsVEGABAR 51 • Foundation Fieldbus36715-EN-130321Contents1 About this document1.1 Function ...
205 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321I2CDisplay112 5 678Fig. 10: Wiring plan, single chamber housing1 Voltage
215 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321123Display12I2CFig. 12: Connection compartment, double chamber housing1
225 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-1303215.5 Wiring plan, double chamber housing Ex dI²C231DisplayTyp:12 5678BusS
235 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321112Fig. 16: Wiring plan, Ex-d double chamber housing1 Voltage supply, si
245 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321I²CDisplayTyp:12 5678BusSim.456123Fig. 19: Electronics and connection com
255 Connecting to power supplyVEGABAR 51 • Foundation Fieldbus36715-EN-130321I2CDisplay112 5 678Fig. 21: Wiring plan external electronics1 Voltage su
266 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-1303216 Set up with the display and adjustment mod
276 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321Fig. 22: Insert display and adjustment module
286 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321 – Save value• [->] key to select: – Menu
296 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321The actual measured value is also displayed i
3ContentsVEGABAR 51 • Foundation Fieldbus36715-EN-1303217.3 Parameter adjustment with AMS™...
306 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321Density0001000kg/dm³6. Enter the requested d
316 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321Iftheadjustmentrangesareexceeded,theme
326 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321The display and adjustment module enables the
336 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321The adjustment unit is thus switched over fro
346 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321Proceed as follows:1. Editthembarvaluein
356 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321ResetBasic adjustmentPeak value, measured val
366 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321Basic adjustment▶Basic adjustment 1DisplayDia
376 Set up with the display and adjustment module PLICSCOMVEGABAR 51 • Foundation Fieldbus36715-EN-130321ServiceBasic adjustment 4DisplayDiagnostics▶S
387 Set up with PACTware and other adjustment programsVEGABAR 51 • Foundation Fieldbus36715-EN-1303217 Set up with PACTware and other adjustment prog
397 Set up with PACTware and other adjustment programsVEGABAR 51 • Foundation Fieldbus36715-EN-1303217.2 Parameter adjustment with PACTwareFurther se
41 About this documentVEGABAR 51 • Foundation Fieldbus36715-EN-1303211 About this document1.1 FunctionThis operating instructions manual provides all
408MaintenanceandfaultrecticationVEGABAR 51 • Foundation Fieldbus36715-EN-1303218 Maintenanceandfaultrectication8.1 MaintainIf the instrumen
418MaintenanceandfaultrecticationVEGABAR 51 • Foundation Fieldbus36715-EN-130321Error Cause RecticationWhen an addition-al instrument is connect
428MaintenanceandfaultrecticationVEGABAR 51 • Foundation Fieldbus36715-EN-130321The serial number is stated on the type label of VEGABAR 51 or on
438MaintenanceandfaultrecticationVEGABAR 51 • Foundation Fieldbus36715-EN-130321Youcandownloadareturnform(23KB)fromourInternethomepage
449 DismountingVEGABAR 51 • Foundation Fieldbus36715-EN-1303219 Dismounting9.1 Dismounting stepsWarning:Before dismounting, be aware of dangerous pro
4510 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-13032110 Supplement10.1 Technical dataGeneral dataPressure type Gauge pressure or gauge press
4610 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321 Ʋ Physical layer according to IEC 61158-2Channel Numbers Ʋ Channel 1 Primary value Ʋ Ch
4710 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321 Ʋ Pressure value -20 … 120 % Adjustmentrangeofthezero/spanadjustmentrelatingtot
4810 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321Nominalrange Overload capacity, max. pressureOverload capacity, min. pres-sure0 … 10 ba
4910 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321 Ʋ Air pressure 860…1060mbar/86…106kPa(12.5…15.4psi)Determination of character
52 For your safetyVEGABAR 51 • Foundation Fieldbus36715-EN-1303212 For your safety2.1 Authorised personnelAll operations described in this operating
5010 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321Long-termstability(accordingtoDIN16086andIEC60770-1)Applies to digitalinterface
5110 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321Producttemperaturedependingontheisolatingliquid(temperature:pabs > 1 bar/14.5
5210 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321 Ʋ Double chamber housing – 1xcableentryM20x1.5(cable:ø5…9mm),1xblind pl
5310 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321 Ʋ Diameter approx. 8mm(0.315in) Ʋ Colour BlueCable entry/plug16) Ʋ External housing
5410 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321 Ʋ External housing IP65,IP66/IP68(0.2bar)Overvoltage category IIIProtection class
5510 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321Parameter listThe following list contains the most important parameters and their meanin
5610 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321• SUB_DEVICE_NUMBER• SENSOR_ELEMENT_TYPE – 0:"non-specic"• display_source_se
5710 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321The two chamber housings are not available with instruments with 4 … 20 mA signal output
5810 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321AluminiumhousinginprotectionratingIP66/IP68(1bar)120 mm (4.72")~ 105 mm (4
5910 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321StainlesssteelhousinginprotectionratingIP66/IP68(1bar)117 mm (4.61")~ 103
62 For your safetyVEGABAR 51 • Foundation Fieldbus36715-EN-1303212.6 CE conformityThisdevicefulllsthelegalrequirementsoftheapplicableECgui
6010 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-13032112368 mm(2.68")68 mm(2.68")92 mm(3.62")42mm(1.65")40mm(1.57")11
6110 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,ange-typechemicalsealDN PN Dkb25 40 115188540 40 150 18 11050 40 16520125
6210 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,ange-typechemicalsealDN PN Dkb25 40 4.53" 0.71"3.35"40 40
6310 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,tubeisolatingdiaphragm11.02"1.26"1.97"DNmmPN G1 L25 40 Rd5
6410 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,tubeisolatingdiaphragm3131 mm (5.16")128 mm (5.04")M55 x 2Fig.
6510 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,capillarylinewithangeisolatingdiaphragm4.53" 0.71"0.71"
6610 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,capillarylinewithcellisolatingdiaphragm0.71"0.71"0.79"0.
6710 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,threadedversionø 32 mm(1.26")ø 26 mm(1.02")ø 39 mm(1.54")ø 6
6810 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-130321VEGABAR51,threadedversionwithtemperatureadapterø 26 mm(1.02")G 1/2 BSW 32 mm(
6910 SupplementVEGABAR 51 • Foundation Fieldbus36715-EN-13032110.4 Industrial property rightsVEGA product lines are global protected by industrial pr
73 Product descriptionVEGABAR 51 • Foundation Fieldbus36715-EN-1303213 Product description3.1 CongurationThe scope of delivery encompasses:• VEGABA
70INDEXVEGABAR 51 • Foundation Fieldbus36715-EN-130321INDEXAAccessories – Display and adjustment module 10 – External display and adjustment unit 10
71NotesVEGABAR 51 • Foundation Fieldbus36715-EN-130321
Printing date:VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany36715-EN-130321All statements concerning scope of delivery, application, practi
83 Product descriptionVEGABAR 51 • Foundation Fieldbus36715-EN-1303212113105436789111214Fig. 2: Layout of the type label (example)1 Instrument type2
93 Product descriptionVEGABAR 51 • Foundation Fieldbus36715-EN-130321Power is supplied via the H1 Fieldbus. A two-wire cable according to Fieldbusspe
Kommentare zu diesen Handbüchern