8 Maintenance and fault rectication
VEGABAR 52 • Probus PA
36719-EN-130321
8 Maintenanceandfaultrectication
8.1 Maintain
If the instrument is used properly, no special maintenance is required
in normal operation.
In some applications, product buildup on the diaphragm can inuence
the measuring result. Depending on the sensor and application, take
precautions to ensure that heavy buildup, and especially a hardening
thereof, is avoided.
If necessary, clean the diaphragm. Make sure that the materials are
resistant to the cleaning process, see resistance list under "Services"
on "www.vega.com". The wide variety of applications of chemical
seals makes special cleaning instructions necessary for each applica-
tion. Please ask the VEGA agency serving you.
8.2 Rectifyfaults
The operator of the system is responsible for taking suitable meas-
ures to rectify faults.
VEGABAR 52 oers maximum reliability. Nevertheless, faults can oc-
cur during operation. These may be caused by the following, e.g.:
Sensor
Process
Voltage supply
Signal processing
The rst measures to be taken are to check the output signals as well
as to evaluate the error messages via the display and adjustment
module. The procedure is described below. Further comprehensive
diagnostics can be carried out on a PC with the software PACTware
and the suitable DTM. In many cases, the causes can be determined
and the faults rectied this way.
Should these measures not be successful, please call in urgent cases
the VEGA service hotline under the phone no.
+49 1805 858550.
The hotline is available to you 7 days a week round-the-clock. Since
we oer this service world-wide, the support is only available in the
English language. The service is free of charge, only the standard
telephone costs will be charged.
The following table describes possible errors and helps to remove
them:
Error Cause Rectication
When an addi-
tional instrument
is connected, the
segment fails.
Max. supply
current of the seg-
ment coupler
exceeded
Measure the current consumption, re-
duce size of segment
Maintenance
Cleaning
Reactionwhenmalfunc-
tions occur
Failure reasons
Faultrectication
24 hour service hotline
CheckingProbusPA