3 Product description
VEGABAR 51 • Probus PA
36714-EN-130321
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
Not in the open
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
Storage and transport temperature see chapter "Supplement -
Technical data - Ambient conditions"
Relative humidity 20 … 85 %
3.5 Accessories and replacement parts
The display and adjustment module PLICSCOM is used for measured
value indication, adjustment and diagnosis. It can be inserted into the
sensor and removed at any time.
You can nd further information in the operating instructions "Display
and adjustment module PLICSCOM" (Document-ID 27835).
The interface adapter VEGACONNECT 4 enables the connection of
communication-capable instruments to the USB interface of a PC. For
parameter adjustment of these instruments, an adjustment software
such as PACTware with VEGA-DTM is required.
You can nd further information in the operating instructions "Interface
adapter VEGACONNECT" (Document-ID 32628).
VEGADIS 61 is suitable for external measured value indication and
adjustment of plics® sensors. It is connected to the sensor with an up
to 25 m long, four-wire, screened standard cable.
You can nd further information in the operating instructions "VE-
GADIS 61" (Document-ID 27720).
Flanges are available in dierent versions according to the following
standards: DIN 2501, EN 1092-1, ANSI B 16.5, JIS B 2210-1984,
GOST 12821-80.
You can nd additional information in the supplementary instructions
manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID
31088).
The measuring instrument holder is used for wall/tube mounting of
VEGABAR series 50 pressure transmitters and VEGAWELL 52 sus-
pension pressure transmitters. Supplied reducers enable the adapta-
tion to dierent instrument diameters. The material used is 316L.
Transport inspection
Storage
Stor
age and transport
temperature
Display and adjustment
module
Interface adapter
External display and
adjustment unit
Flanges
Measuring instrument
holder
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 75 76

Kommentare zu diesen Handbüchern

Keine Kommentare