Vega VEGABAR 52 4 … 20 mA_HART - climate compensated Bedienungsanleitung Seite 57

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 56
57
10 Supplement
VEGABAR 52 • 4 … 20 mA/HART - climate compensated
36718-EN-130321
Ʋ Conguration four wires, one suspension wire, one breather capillary,
screen braiding, metal foil, mantle
Ʋ Wire cross-section 0.5 mm² (AWG 20)
Ʋ Wire resistance <0.036Ω/m(0.011Ω/ft)
Ʋ Tensile strength > 1200 N (270 pounds force)
Ʋ Standard length 5 m (16.4 ft)
Ʋ Max. length 1000 m (3281 ft)
Ʋ Min. bending radius at 25 °C/77 °F 25 mm (0.985 in)
Ʋ Diameter approx. 8 mm (0.315 in)
Ʋ Colour - Non-Ex version Black
Ʋ Colour - Ex-version Blue
Electromechanical data - version IP 68
Connection cable between IP 68 instrument and external housing:
Ʋ Conguration four wires, one suspension wire, one breather capillary,
screen braiding, metal foil, mantle
Ʋ Wire cross-section 0.5 mm² (AWG 20)
Ʋ Wire resistance <0.036Ω/m(0.011Ω/ft)
Ʋ Standard length 5 m (16.40 ft)
Ʋ Max. length 180 m (590.5 ft)
Ʋ Min. bending radius at 25 °C/77 °F 25 mm (0.985 in)
Ʋ Diameter approx. 8 mm (0.315 in)
Ʋ Colour Blue
Cable entry/plug
16)
Ʋ External housing 1 x cable gland M20 x 1.5 (cable: ø 5 … 9 mm), 1 x
blind plug M20 x 1.5
or:
1␣xplug(dependingontheversion),1␣xblindstopper
M20␣x␣1.5
Spring-loaded terminals for wire cross-
section up to
2.5 mm² (AWG 14)
Display and adjustment module
Voltage supply and data transmission through the sensor
Indication LC display in dot matrix
Adjustment elements 4 keys
Protection rating
Ʋ unassembled IP 20
Ʋ mounted into the sensor without cover IP 40
Material
Ʋ Housing ABS
Ʋ Inspection window Polyester foil
16)
DependingontheversionM12x1,accordingtoISO4400,Harting,7/8"FF.
Seitenansicht 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 75 76

Kommentare zu diesen Handbüchern

Keine Kommentare