4 Mounting
4.1 General instructions to use the instrument
Makesurethatallpartsoftheinstrumentcomingindirectcontact
withtheprocess,especiallythesensorelement,processsealand
processtting,aresuitablefortheexistingprocessconditions,such
asprocesspressure,processtemperatureaswellasthechemical
properties of the medium.
Youcanndthespecicationsinchapter"Technical data" and on the
nameplate.
Usetherecommendedcables(seechapter"Connecting to power
supply") and tighten the cable gland.
You can give the instrument additional protection against moisture
penetrationbyleadingtheconnectioncabledownwardinfrontofthe
cableentry.Rainandcondensationwatercanthusdraino.Thisap-
pliesmainlytooutdoormountingaswellasinstallationinareaswhere
high humidity is expected (e.g. through cleaning processes) or on
cooled or heated vessels.
Theventilationfortheelectronicshousingisrealisedviaalterele-
ment in the vicinity of the cable glands.
2
1
2
1
2
1
1
2
Fig. 10: Position of the lter element with single and double chamber housing
1 Filter element for ventilation of the electronics housing
2 Blind plug
Information:
Makesurethatthelterelementisalwaysfreeofbuildupduring
operation. A high-pressure cleaner may not be used for cleaning.
DPowelementsarecalculatedforcertainpipelineandoperating
data. Therefore, check the pipeline data before installation at the
measuring point and compare the measurement loop number.
Suitability for the process
conditions
Moisture
V
entilation
Eectivepressuretrans-
mitter