7 Set up with the display and adjustment module
SOLITRAC 31 • 4 … 20 mA/HART - four-wire
43387-EN-131119
Select "Linearization - New"toentertherstpoint.
Select "Determine count rate"toentertherstpoint.
The determination of the actual count rate lasts 2 minutes. After the
count rate has been determined, you can accept the value (ct/s).
The count rate is stated in ct/s. This is the number of counts per sec-
ond, i.e. the measured radioactive radiation dose actually reaching
the sensor.
Enter now the corresponding level (m).
By doing so, you assign a respective level to the actual count rate.
Accept the value pair with "OK".
Depending if you have started with full or empty vessel, you have to
continueemptyingorllingthevessel.
Alsocarryoutsuchalinearizationwithseveraldierentllingheights
if you have a linear vessel.
Bydoingso,youcaninuencethemeasurementreliabilityofthe
sensor. The more linearization points you enter and the bigger the
dierencebetweentherstandthelastlinearizationpoint,themore
reliable the measurement will be.
If you have a non-linear vessel (e.g. spherical tank), you have to carry
out this adjustment with as many points as possible.
A maximum of 32 linearisation points is possible.
Note:
Ifyoucannotllthevesselduringtheadjustmentproceduretoatleast
60 % of the max. level, it is possible to carry out the full adjustment
byswitchingotheradiation.Theswitched-oradiationsimulatesa
100%lling.