6 Set up with the display and adjustment module
VEGABAR 81 • 4 … 20 mA/HART
45018-EN-131010
Setup: Settings, e.g., for measurement loop name, application, units,
position correction, adjustment, signal output
Display: Settings, e.g., for language, measured value display, lighting
Diagnosis: Information, e.g. on instrument status, pointer, measure-
ment reliability, simulation
Additional adjustments: PIN, date/time, reset, copy function
Info: Instrument name, hardware and software version, date of manu-
facture, sensor features
In the main menu item "Setup", the individual submenu items should
be selected one after the other and provided with the correct param-
eter values.
The following submenu points are available:
In the following paragraphs the menu items of the menu "Setup" for
electronicdierentialpressuremeasurementaredescribed.Depend-
ingontheselectedapplication,dierentparagraphsareimportant.
The additional menu items of the menu "Setup" as well as the com-
plete menus "Display", "Diagnosis", "Additional settings" and "Info"
are described in the operating instructions of the master sensor.
In the menu item "Sensor TAG" you edit a twelve digit measurement
loop designation label.
You can enter an unambiguous designation for the sensor, e.g. the
measurement loop name or the tank or product designation. In digital
systems and in the documentation of larger plants, a singular desig-
nationmustbeenteredforexactidenticationofindividualmeasuring
points.
The available digits comprise:
Letters from A … Z
Numbers from 0 … 9
Special characters +, -, /, -
In this menu item you activate/deactivate the slave for electronic dif-
ferential pressure and select the application.
Ifyouhaveconnectedaslavesensor,youconrmthiswith"Activate".