6AdjustmentwiththedisplayandadjustmentmodulePLICSCOM
VEGADIF 65 • 4 … 20 mA
36236-EN-130417
1. Editthe%valueinthemenuitem"Min. adjustment"with[OK].
Min.adjustment
0.00 %
=
0.0000 bar
0.0000 bar
2. Settherequestedvaluewith[+] and [->].
3. Conrmwith[OK]andedittherequestedbarvalue.
4. Settherequestedbarvaluewith[+] and [->].
5. Conrmwith[OK]andmovetomax.adjustmentwith[->].
Foranadjustmentwithlling,simplyentertheactualmeasuredvalue
indicated at the bottom of the display.
Themin.adjustmentisnished.
Proceedasfollows:
1. Editthe%valueinthemenuitem"Max. adjustment"with[OK].
100.00 %
=
0.5000 bar
0.0000 bar
Information:
If the instrument has not yet been adjusted, the displayed pressure for
100%correspondstothenominalmeasuringrangeofthesensor(in
the above example 500 mbar).
2. Settherequestedvaluewith[->] and [OK].
3. Conrmwith[OK]andedittherequestedmbarvalue.
4. Settherequestedvaluewith[+] and [->].
5. Conrmwith[OK]andmovetothemenuoverviewwith[ESC].
Foranadjustmentwithlling,simplyentertheactualmeasuredvalue
indicated at the bottom of the display.
Themax.adjustmentisnished.
Forthemin.adjustmentwithdensity,allingofthevesselisnot
necessary. The numeric examples are stated in chapter Mounting,
Measurement setup, Density and interface of this instructions manual.
Proceedasfollows:
1. Editthe%valueinthemenuitem"Min. adjustment"with[OK].
Min.adjustment
0.00 %
=
0.0000 bar
0.0000 bar
2. Settherequestedvaluewith[+] and [->],forexample100%.
3. Conrmwith[OK]andedittherequestedbarvalue.
4. Settherequestedbarvaluewith[+] and [->], for example
29.4 mbar.
5. Conrmwith[OK]andmovetomax.adjustmentwith[->].
Max. adjustment with
lev
el
Min. adjustment with
density
Seitenansicht 44